ZYT PRODUCT CATALOG
ZYT-1000GF – KTA50-G3
Explore diesel generator sets by engine brand and power range. Compare individual configurations, then discuss voltage, frequency, enclosure and operating duty with our team.



Cummins
ZYT-1000GF – KTA50-G3
Configuration data for project selection. Confirm the operating duty and destination requirements in your quotation.
- Rated power
- 1000kw / 1250kva
- Maximum power
- 1100kw / 1375kva
- Engine
- KTA50-G3
- Frequency
- 50Hz/60Hz
- Voltage
- 220/380V、230/400V、240/415V etc.
- Fuel
- Diesel
Specifications vary with frequency, operating conditions and selected options. Product images illustrate the equipment type; the final configuration and bill of materials are confirmed with the quotation.
Generator specifications
| Model | ZYT-1000GF | ||||||
|---|---|---|---|---|---|---|---|
| Rated Power | 1000kw / 1250kva | ||||||
| Max Power | 1100kw / 1375kva | ||||||
| Voltage | 220/380V、230/400V、240/415V etc. | ||||||
| Frequency | 50Hz/60Hz | ||||||
| Phase | Single/Three phase | ||||||
| Power factor | 0.8 | ||||||
| Fuel tank capacity (L) | 1500L (Silent) | ||||||
| Dimensions (L×W×H) | 5100*2300*2600 (Open) | 6500*2500*2950mm (Silent) | |||||
| Weight | 9500kg (Open) | 13350kg (Silent) | |||||
Engine data
| Brand | Cummins | ||
|---|---|---|---|
| Model | KTA50-G3 | ||
| Rated Power | 1227kW(1500 RPM)/ 1380kW(1800 RPM) | ||
| Max Power | 1227kW(1500 RPM)/ 1380kW(1800 RPM) | ||
| Cylinder | 16 | ||
| Bore×Stroke | 159*159mm | ||
| Displacement | 50.3L | ||
| Compression ratio | 13.9:1 | ||
| Fuel system | Cummins PT System | ||
| Aspiration | Turbocharged,Aftercooled | ||
| Fuel Consumption (1500 RPM) | 100% 203 g/kWh | 75% 206 g/kWh | |
| 50% 215 g/kWh | 25% 235 g/kWh | ||
| Fuel Consumption (1800 RPM) | 100% 204 g/kWh | 75% 207 g/kWh | |
| 50% 220 g/kWh | 25% 249 g/kWh | ||
Alternator data
| Brand | Mingxing | ||
|---|---|---|---|
| Model | MX-1000-4 | ||
| Exciter type | Brushless | ||
| Frequency | 50Hz/60Hz | ||
| Speed | 1500rpm/1800rpm | ||
| Power factor | 0.8 | ||
| Phase | Single/Three phase | ||
| Voltage adjust range | ≥5% | ||
| Voltage regulation NL-FL | ≤±1% | ||
| Insulation Grade | H | ||
| Protection Grade | IP23 |
Controller functions
| Starting mode | automatic / stop / by hand | ||
|---|---|---|---|
| Auto start time(S) | 3-60 (adjustable) | ||
| Display parameter | VAB, VBC, VCA, IA, IB, IC, voltage of battery, cooling water temp, oil pressure, alternator frequency, output power, fault information | ||
| Configure | LCD、TEM、English operation system, pre-supply oil system | ||
| Insurance & safety equipment | with proteciton of over-voltage, under-voltage, over-current, super-power, low oil pressure, high water temperature, stop, speeding, lack of speed, frequency overrun, failure to start, ect. |
Standard accessories
| Standard Accessories Name | Quantity | ||||||
|---|---|---|---|---|---|---|---|
| Diesel Engine | 1 set | ||||||
| Brushless Alternator | 1 set | ||||||
| Controller Panel | 1 set | ||||||
| Cooling water tank | 1 set | ||||||
| High-efficient silencer | 1 pc | ||||||
| Standard air filter, oil filter, fuel filter (built-in) | 1 unit | ||||||
| Operating manual | 1 copy | ||||||
| Installation Device (Expand shock absorption tie-in, shock absorption pad, wire between gen-set and storage battery, flexible connection with muffler) | 1 unit |
Selection & support
Before ordering
Specify rated load, starting load, voltage, frequency, ambient temperature, altitude, enclosure and operating hours.
Documentation & service
Agree the technical schedule, inspection scope, manuals, service parts and destination requirements before purchase.
Discuss ZYT-1000GF – KTA50-G3
Send the destination, load, voltage, frequency and required quantity.